Customization: | Available |
---|---|
Material: | Aluminum |
Usage: | for Manufacture |
Still deciding? Get samples of US$ 24.31/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Slim Installation Height and High Air Flow Rate with lowest Noise
Impeller Sizes: from 30mm to 80mm diameter;
Sound Level: from 32dBA to maximum 48dBA according different rotation speed;
Airflow: maximum to 600CMH, Cubic Meter per Hour, equal to approx. 353CFM , Cubic Feet per Minute;
Air Pressure: Maxim to 80Pa, equal to 8.16mm H2O and to 0.32 inches H2O;
Power: Maximum motor input power goes to 100W motor diameter 80mm.
General Characters:
1-1 |
Rated Voltage
|
24 VDC |
1-2 |
Operating Voltage
|
16~28 VDC |
1-3 |
Low-Start Voltage
|
15 VDC |
1-4 |
Rated Speed
|
2600RPM |
1-5 |
Input Current
|
0.17A |
1-6 |
Input Power
|
4.08W |
1-7 |
Acoustical Noise
|
40dB(A) |
1-8 |
Life Expectance
|
50,000Hours(L10)
At 40ºC room, humidity 15%~65%RH
|
1-9 |
Direction of Rotation
|
Anti-clockwise see on motor |
1-10 |
Direction of Air Flow
|
All round |
1-11 |
Insulation Class
|
Class B |
1-12 |
Insulation Resistance
|
50Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1-13 |
Motor Protection
|
Locked rotor protection
Polarity protection Automatic restart capability |
1-14 |
Speed Control
|
Control input 0~10VDC |
1-15 |
Dielectric Strength
|
5mA maximum at 500VAC 50Hz five second Between frame and (+) terminal |
1-16 |
Signal Output
|
No |
Mechanical Characters:
2-1 | Dimension |
48mm X 50mm X 705mm (see dimension drawing) |
2-2 | Material of Impeller |
Steel |
2-3 | Number of Blades |
22 |
2-4 | Impeller Plate |
Injection-moulded round sheet-metal plate |
2-5 | Mounting position |
Any |
2-6 | Surface of Rotor |
Electrophoresis |
2-7 | Bearing System |
NMB ball bearing |
2-8 | Lead Wire |
Red , Black, White AWG22# |
2-9 | Weight |
837g |
2-10 | Package |
Standard |
Electrical Protection:
3-1 |
Locked-rotor Protection
|
Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage.
|
3-2 |
Maximum Current
under Locked Rotor
|
A, Typical inrush current when the motor is trying to re-start under locked rotor conditions is 2~4 times the normal running current reoccurring and for 16~20% of restarting cycle period.
B, If he CL function is used this restarting inrush current is about the same as the normal running current.
|
3-3 |
Reverse Polarity
Protection
|
No damage if the positive and negative leads are reversed under maximum operation voltage conditions.
|
3-4 |
Over Voltage Protection
|
The circuit will be shut down automatically when input voltage over 30VDC. And re-started when Voltage down to 30VDC below.
|
3-5 |
Soft Start
|
In 5 seconds after power on and speed control voltage gets to 1.5V.
|
Enviromental Characters:
4-1 |
Operating Temperature
|
-25ºC to 60ºC
|
4-2 |
Storage Temperature
|
-40ºC to 75ºC
|
4-3 |
Operating Humidity
|
5% to 90% RH
|
4-4 |
Storage Humidity
|
5% to 95% RH
|
4-5 |
Drop Test
|
In minimum packaging condition fan withstand each one drop of three faces from 30cm distance height onto 10mm thickness of wooden board
|
4-6 |
Vibration Test
|
Sine Wave.
Displacement amplitude: 0.75mm (Equivalent 10G).
Frequency Range: 10Hz~55Hz / 30 sec. 55Hz~10Hz / 30 sec
Linear Scanning 120 Cycle
Endurance timer per axis: 2 Hours
Orientation: X,Y,Z.
|
4-7 |
Shock Test
|
Apply peak acceleration 50g and keep duration of the pulses for
11ms (Half sine wave).
|
4-8 |
All the material meets RoHS standard.
|