Customization: | Available |
---|---|
Material: | Aluminum |
Usage: | for Manufacture |
Still deciding? Get samples of US$ 16.82/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Best-Selling China Manufacture Quality Electric Fireplace Machine DC Ptc Heater Horizontal Cross Flow Fan With Blower
Model:PC50B24248B
Impeller Sizes: from 30mm to 80mm diameter;
Sound Level: from 32dBA to maximum 48dBA according different rotation speed;
Airflow: maximum to 600CMH, Cubic Meter per Hour, equal to approx. 353CFM , Cubic Feet per Minute;
Air Pressure: Maxim to 80Pa, equal to 8.16mm H2O and to 0.32 inches H2O;
Power: Maximum motor input power goes to 100W motor diameter 80mm.
General Characters:
1-1 | Rated Voltage | 24 VDC |
1-2 | Operating Voltage | 16 ~ 28 VDC |
1-3 | Rated Speed | 2400 RPM |
1-4 | Input Current | 0.33 A |
1-5 | Input Power | 7.92 W |
1-6 | Acoustical Noise | 44 dB(A) |
1-7 | Life Expectance | 50,000Hours(L10) At 40ºC room, humidity 15%~65%RH. |
1-8 | Direction of Rotation | Clockwise seen on motor |
1-9 | Insulation Class | Class B |
1-10 | Insulation Resistance | 50 Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1-11 | Motor Protection | Locked rotor protection Polarity protection Automatic restart capability |
1-12 | Speed Control | Control input 0~10VDC |
1-13 | Dielectric Strength | 5mA maximum at 500VAC 50Hz five second Between frame and (+) terminal |
1-14 | Air Flow | 123.59 CFM / 210 m3/H |
1-15 | Static Pressure | 4.59 mmH2O / 45 Pa |
1-16 | Protection Type | IP44 |
Environmental Characters:
2-1 | Dimension | 70 x 70 x 310 (see dimension drawing) |
2-2 | Material of Impeller | Aluminum alloy |
2-3 | Number of Blades | 22 |
2-4 | Bearing System | NMB ball bearing |
2-5 | Mounting Position | Any |
2-6 | Lead Wire | Red , Black, White AWG22# |
2-7 | Package | Standard |
Electrical Protection
3-1 | Locked-rotor Protection | Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
3-2 | Reverse Polarity Protection | No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
3-3 | Over Voltage Protection | The circuit will be shut down automatically when input voltage over 15VDC. And re-started when Voltage down to 15VDC below. |
3-4 | Soft Start | In 5 seconds after power on and speed control voltage gets to 1.5V. |
3-5 | RoHS | All the material meets RoHS standard. |
Environmental Characters
4-1 | Operating Temperature | -25ºC to 60ºC |
4-2 | Storage Temperature | -40ºC to 75ºC |
4-3 | Operating Humidity | 5% to 90% RH |
4-4 | Storage Humidity | 5% to 95% RH |
4-5 | RoHS | All the material meets RoHS standard. |
Performance Curve:
Testing Condition
Input Voltage----Operating voltage (24 VDC)
Temperature-----Room temperature
Humidity---------65%RH
Test distance-----1m
Outline Drawing
Note
1. Connection line 3X (Red, Black, White AWG22#);
Red=+24VDC, White=0-10VDC, Blue=GND.
Safety Requirements
Products of the same series
Model Part No. |
Rated Voltage VDC |
Air Flow M3/H |
Air Pressure Pa |
Rated Speed RPM |
Sound Level dB(A) |
Total Length mm |
PC50B1298B | 12 | 60 | 40 | 2400 | 34 | 166 |
PC50B2498B | 24 | 60 | 40 | 2400 | 34 | 166 |
PC50B12158B | 12 | 110 | 45 | 2400 | 42 | 226 |
PC50B24158B | 24 | 110 | 45 | 2400 | 42 | 226 |
PC50B12198B | 12 | 150 | 45 | 2400 | 43 | 266 |
PC50B24198B | 24 | 150 | 45 | 2400 | 43 | 266 |
PC50B12248B | 12 | 210 | 45 | 2400 | 44 | 310 |
PC50B24248B | 24 | 210 | 45 | 2400 | 44 | 310 |
PC50B12290B | 12 | 260 | 45 | 2400 | 44 | 363 |
PC50B24290B | 24 | 260 | 45 | 2400 | 44 | 363 |
PC50B12358B | 12 | 330 | 45 | 2400 | 43 | 422 |
PC50B24358B | 24 | 330 | 45 | 2400 | 43 | 422 |
PC50B12418B | 12 | 395 | 45 | 2400 | 43 | 476 |
PC50B24418B | 24 | 395 | 45 | 2400 | 43 | 476 |
Q:How about the delivery time ?
A:Within 25 days after we receive the order.