Customization: | Available |
---|---|
Rated Speed: | 2600 Rpm |
Rated Voltage: | 12 VDC |
Still deciding? Get samples of US$ 10.66/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sell High-Quality Multifunctional Energy-Saving Heater Solar Suppliers Centrifugal Blower Fan
Model:PC40B12250C
Impeller Sizes: from 30mm to 80mm diameter;
Sound Level: from 32dBA to maximum 48dBA according different rotation speed;
Airflow: maximum to 600CMH, Cubic Meter per Hour, equal to approx. 353CFM , Cubic Feet per Minute;
Air Pressure: Maxim to 80Pa, equal to 8.16mm H2O and to 0.32 inches H2O;
Power: Maximum motor input power goes to 100W motor diameter 80mm.
General Characters:
1-1 | Rated Voltage | 12 VDC |
1-2 | Operating Voltage | 9 ~ 15 VDC |
1-3 | Rated Speed | 2600 RPM |
1-4 | Input Current | 0.25 A |
1-5 | Input Power | 3 W |
1-6 | Acoustical Noise | 35 dB(A) |
1-7 | Life Expectance | 50,000Hours(L10) At 40ºC room, humidity 15%~65%RH. |
1-8 | Direction of Rotation | Clockwise seen on motor |
1-9 | Insulation Class | Class B |
1-10 | Insulation Resistance | 50 Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1-11 | Motor Protection | Locked rotor protection Polarity protection Automatic restart capability |
1-12 | Speed Control | Control input 0~10VDC |
1-13 | Dielectric Strength | 5mA maximum at 500VAC 50Hz five second Between frame and (+) terminal |
1-14 | Air Flow | 68.27 CFM / 116 m3/H |
1-15 | Static Pressure | 2.76 mmH2O / 27 Pa |
1-16 | Protection Type | IP44 |
Environmental Characters:
2-1 | Dimension | 61 x 63 x 319 (see dimension drawing) |
2-2 | Material of Impeller | Aluminum alloy |
2-3 | Number of Blades | 22 |
2-4 | Bearing System | NMB ball bearing |
2-5 | Mounting Position | Any |
2-6 | Lead Wire | Red , Black, White AWG22# |
2-7 | Package | Standard |
Electrical Protection
3-1 | Locked-rotor Protection | Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
3-2 | Reverse Polarity Protection | No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
3-3 | Over Voltage Protection | The circuit will be shut down automatically when input voltage over 15VDC. And re-started when Voltage down to 15VDC below. |
3-4 | Soft Start | In 5 seconds after power on and speed control voltage gets to 1.5V. |
3-5 | RoHS | All the material meets RoHS standard. |
Environmental Characters
4-1 | Operating Temperature | -25ºC to 60ºC |
4-2 | Storage Temperature | -40ºC to 75ºC |
4-3 | Operating Humidity | 5% to 90% RH |
4-4 | Storage Humidity | 5% to 95% RH |
4-5 | RoHS | All the material meets RoHS standard. |
Performance Curve:
Testing Condition
Input Voltage----Operating voltage (12 VDC)
Temperature-----Room temperature
Humidity---------65%RH
Test distance-----1m
Outline Drawing
Note
1. Connection line 3X (Red, Black, White AWG22#);
Red=+12VDC, White=0-10VDC, Blue=GND.
Safety Requirements
Products of the same series
Model Part No. |
Rated Voltage VDC |
Air Flow M3/H |
Air Pressure Pa |
Rated Speed RPM |
Sound Level dB(A) |
Total Length mm |
PC40B1298C | 12 | 30 | 15 | 2600 | 30 | 145 |
PC40B2498C | 24 | 30 | 15 | 2600 | 30 | 145 |
PC40B12160C | 12 | 65 | 20 | 2600 | 33 | 207 |
PC40B24160C | 24 | 65 | 20 | 2600 | 33 | 207 |
PC40B12198C | 12 | 92 | 25 | 2600 | 34 | 245 |
PC40B24198C | 24 | 92 | 25 | 2600 | 34 | 245 |
PC40B12250C | 12 | 116 | 27 | 2600 | 35 | 295 |
PC40B24250C | 24 | 116 | 27 | 2600 | 35 | 295 |
PC40B12300C | 12 | 138 | 29 | 2600 | 36 | 347 |
PC40B24300C | 24 | 138 | 29 | 2600 | 36 | 347 |
PC40B12348C | 12 | 162 | 32 | 2600 | 37 | 399 |
PC40B24348C | 24 | 162 | 32 | 2600 | 37 | 399 |
PC40B12420C | 12 | 195 | 34 | 2600 | 38 | 467 |
PC40B24420C | 24 | 195 | 34 | 2600 | 38 | 467 |
Q:How about the delivery time ?